Printer Configuration and Adjustment
Calibrate the Ribbon and Media Sensors
144
P1066582-003 ZT400 Series™ User Guide 8/25/15
5. Pull the media into the printer so that only the backing is between the media sensors.
6. Remove the ribbon (if used).
7. Rotate the printhead-open lever (1) downward until it locks the printhead in place.
8. Press PAUSE to begin the media calibration process.
•The PAUSE light turns off.
•The SUPPLIES light flashes.
The control panel displays:
1
MEDIA/RIBBON CAL
CALIBRATING
PLEASE WAIT