28
8.5 Replace the filter drier
Switch off the device before opening it and pull out the mains plug.
1. Take off the front panel, Remove the filter cartridge on the left side and replace
it with a new one. When inserting a new filter cartridge, observe the flow
direction (FLOW arrow must point downwards).
2. conform that the new filter drier is well fixed.
3. Put the front panel back on and reconnect the power plug.
4. In function mode, to use the or key to select FILTER DRIER
press key to reset the count
8.6 Hose compensation
You can service yourself by inputting a new quantity of refrigerant as a
compensation when the recharging occurs.
note: we strongly claim to use the default setting of compensation
8.7 Pressure rise wait
Setting the waiting time that the refrigerant evaporate in the A/C system , during the
recovery operation phase.the more minutes you set,the more percent of gas could
be recovered.