3.6. MP
A 1606 PA CONTROL UNIT
- Outer dimensions: 483 x 177 x 55 mm.
- Operating voltage: 24VDC supplied from the MPA1600
Operation Unit.
- Current drain maximum: 300mA. (integrated in the MPA 1600)
- Microphone input level: 10mV typical (dynamic mic.)
- Ingress Protection (IP): 22
- Compass safe distance (standard): 80cm
- Compass safe distance (steering): 50cm
-
3.7. MPA 1643 PA CONTROL UNIT
- Outer dimensions: 160 x 360 mm.
- Operating voltage: 24VDC supplied from the MPA1600
Operation Unit.
- Current drain maximum: 300mA. (integrated in the MPA 1600)
- Microphone input level: 10mV typical (dynamic mic.)
- Ingress Protection (IP): 44
- Compass safe distance (standard): 80cm
- Compass safe distance (steering): 50cm
3.8. AMPLIFIERS
Model: PA-6336
ELECTRICAL
Power output (THD 1%) 360W (RMS)
Max load: 4 ohm (38V)
8 ohm (50V)
13,6 ohm (70V)
27,8 ohm(100V)
Frequency Response (+1/-3dB) 70Hz to 20KHz
THD at 1 KHz, Rated Output Less than 1%
HPF -3dB at 400Hz
Signal to Noise Ratio Better than 95dB
Input Sensitivity/Impedance 1V/10K ohm Balanced
Input Level Adjustment (service mode) -12dB to 0dB
GENERAL
Power source (primary) AC 230V (220/240) 50Hz/60Hzor
(primary alternative) AC 115V (110/120)
(backup) DC 24V
Dimensions W:482 x H:132 x D:280 mm
Weight 21Kg.
Compass safe distance: Ref Cabinet data