Access Control System Installation Guide
iii
(I) Share power with the lock:
NC LOCK
+
-
-
-
+
DC 12V
NO LOCK
+
-
-
-
+
DC 12V
FR107
FR107
White
SEN
Black
GND
Gray
BUT
Blue
NO
Red
COM
Yellow
NC
Orange
AL-
Orange
AL+
Red
+12V
Black
GND
Red
+12V
Black
GND
White
SEN
Black
GND
Gray
BUT
Blue
NO
Red
COM
Yellow
NC
Orange
AL-
Orange
AL+
(II) Separate power for both device and lock:
NC LOCK
+
-
-
-
+
DC 12V
NO LOCK
+
-
-
+
DC 12V
FR107
-
+
-
DC power
FR107
+
-
DC power
-
+
+
White
SEN
Black
GND
Gray
BUT
Blue
NO
Red
COM
Yellow
NC
Orange
AL-
Orange
AL+
Red
+12V
Black
GND
Red
+12V
Black
GND
White
SEN
Black
GND
Gray
BUT
Blue
NO
Red
COM
Yellow
NC
Orange
AL-
Orange
AL+
①: ‘I’: device output current, ‘ULOCK’: lock voltage, ‘ILOCK’: lock current.
Device share power with the lock:
ULOCK=12V, I-ILOCK>1A……;
And the lock is near to the device.
Device separate power with the lock:
A. ULOCK =12V I-ILOCK ≤1A;
B. ULOCK ≠12V;
C. The lock is far apart from the device.
D. We suggest user select “separate
power for both device and lock”.