8
Leave the cleaning soluon to dissolve the scale deposit for about 15 minutes. Store your cleaning soluon in
a safe place or dispose of according to your local council regulaons, never pour it into the rainwater drainage
system or into sewers.
Rinse the electrode using clean water and put back into posion.
Open the isolaon valves (if applicable) and restart the chlorinator and the ltraon system.
* If you do not use a commercially available cleaning soluon, you can manufacture it yourself by
carefully mixing 1 volume of hydrochloric acid with 9 volumes of water (Warning: always pour the acid
into the water and not the opposite and wear suitable protecve equipment!).
Troubleshoong
EiXpert Text Displayed Possible causes Soluons
CLEANING The self-cleaning cycle is
automac; this message is
not an error code but an
informaon message.
Wait for about 10 minutes and chlorine
producon will resume automacally at the
previously set level.
“Check
Salt
warning
displayed
CHECK SALT Salinity is under 3,000ppm.
Pool water temperature too
low (< 18 °C, variable).
Cell scaled up or worn.
Add salt to the pool to keep the level at
4,000ppm. If you do not know the salt level
or how to test it, consult your pool care
professional.
Display warning will come on when the
water is too cold. No acon required.
Clean or replace the cell.
“Flow
indicator
on
NO FLOW Stop or failure of the
ltering pump.
Presence of air or gas in the
cell (not lling with water).
By-pass valves closed.
Check lter, pump basket & skimmers and
clean them if necessary. Ensure all valves
are set for normal operaon.
If using a variable speed pump ensure the
speed seng is high enough for adequate
ow through the cell.
If sucon cleaner is connected to skimmer
check cleaner for blockages or restricon
of ow
CHECK PUMP This message is displayed
alternately with "NO FLOW"
if the situaon connues.
Check the pump connecon
into the power pack is
secure.
Perform the same checks as above.
Note: that EiXpert has built in pump
protecon. This means that EiXpert will
supply power for 4 mins, if there is no ow
detected it will retry aer 20mins. It will
repeat this again and if sll no ow it will
enter into standby and require restarng.
All schedules will remain in memory.
CHECK CELL Short-circuit in the cell or
cable disconnected/badly
connected.
Worn electrode.
Check the cell connecons.
Replace the cell.
Have the control box (electronic board
and transformer) checked by a qualied
technician if necessary.
OVERHEAT Device internal temperature
over 70 °C.
Device internal temperature
over 80 °C.
The device reduces its producon to 50 %.
Producon stops.
Producon restarts automacally when the
temperature drops.
X
The device no longer stores
the me.
Check the condion of the baery.
Replace it if necessary (3 V baery, type
"CR2032").
==> If the problem continues contact your pool care professional.