11
2.2 I Installing the ow switch
• Failure to comply with these instrucons could lead to the destrucon of the cell. The manufacturer
cannot be liable in this case.
• The ow switch has a direcon for installaon (arrow indicated on it showing the ow direcon for
the water). Make sure that it is correctly placed on its xture collar so that it stops the appliance's
producon when ltering is stopped.
• The ow switch and its xture collar (supplied) must be installed just in front of the cell and aer a
possible valve, in the ow secon that supplies the cell.
• Tighten the nuts by hand.
G 3/4 F
G 3/4 M
G 1/2 M
G 1/2 F
Installaon of the ow switch and the installaon kit