- 12 -
5) Turn the Module selector (VR1) anticlockwise by one detent.
Press the [STORE] key (SW3).
Repeat this sequence to “PLAY”.
( When “TIME”, 7 segment LED is displayed “-12”.
When “DELAY”, 7 segment LED is displayed “-11”.
When “RHYTHM”, 7 segment LED is displayed “0”. )
Make sure “ok” appears on the 7 segment LED.
6) Make sure that the following indications appear on the 7 segment LED.
When the 7 segment LED is correctly displayed, Restart the G1 by press the [BANK
UPTAP] key (SW1).
Module selector 7 segment LED
PLAY 0
RHYTHM 1
PATCH LEVEL 2
COMP/EFX 3
DRIVE 4
GAIN 5
EQ Lo 6
EQ Mid 7
EQ Hi 8
ZNR/AMP 9
MODULATION 10
RATE 11
DELAY 12
TIME 13
REVERB 14
DECAY 15
②④⑯⑱
※It is NG that a
value changes in a
click.
0
1
2
3
4
5
6
7 8
9
10
11
12
13
14
15
There is a change in
a click
(allowance)=
NG
It is OK to change with a
dark color.
It is OK to change with a
dark color.
①③⑤~⑮⑰⑲
※A value changes in
a range of arrow
Inspection judgment standard of 16 click setting.
0->1、2->1
13->14、15->14
Attention at the time
of setting
allowance
It must
consciously setting
that center of
allowance.