Page #26 background imageLoading...
Page #26 background image
User Manual
24
Error
code
Malfunction Cause Solution
EB1
“Length checking channel
of the hoist steel wire”
voltage is lower than the
min limitation
No steel wire on hoist Adjust length of steel wire
No measurable sensor exist for
hoisting
Install sensor and revise this
function at program data
Steel wire length no adjust well
Adjust steel wire length and
surface
Wrong steel wire/hoist parameter
at program data
Check parameter of program data
No counter input defined at
configuration
Change I/O configuration
Counter input fault Change Iflex
EB2
“Length checking channel
of steel wire on hoist”
voltage exceed the
limitation
Steel wire completely twining
hoist ( only possible at EB2)
Adjust length of steel wire
Refer to EB1 Refer to EB1
EB3
“Checking channel of hook
height” voltage exceed the
limitation
No steel wire between hook and
forward oriented wheel
Refer to EB1
Refer to EB1
EDD
Battery empty
Check out low voltage of the two
ports of battery
Setting RTC and change battery
Temporary measurementpress
alarm stop key when
Operation without data loader
EFD
LMB watch dog overtime
This function shall be started over
5 min. like writing flash PROM
After finish programming,
information is not automatically
started