Chapter 23 Multicast
XS3700 Series User’s Guide
199
The following table describes the labels in this screen.
23.4.5 MLD Snooping-proxy Filtering Profile
Use this screen to create an MLD filtering profile and set the range of the multicast address(es).
Click the Filtering Profile link in the Advanced Application > Multicast > IPv6 Multicast >
MLD Snooping-proxy > Filtering screen to display the screen as shown.
Figure 125 Advanced Application > Multicast > IPv6 Multicast > MLD Snooping-proxy > Filtering >
Filtering Profile
Table 100 Advanced Application > Multicast > IPv6 Multicast > MLD Snooping-proxy > Filtering
LABEL DESCRIPTION
Active Select this option to enable MLD filtering on the Switch.
Port This field displays the port number.
* Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row
first to set the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
Group Limit Select this option to limit the number of multicast groups this port is allowed to join.
Max Group Num. Enter the number of multicast groups this port is allowed to join. Once a port is registered
in the specified number of multicast groups, any new MLD Report message is dropped on
this port.
Filtering Profile Select the name of the MLD filtering profile to use for this port. Otherwise, select Default
to prohibit the port from joining any multicast group.
You can create MLD filtering profiles in the Multicast > IPv6 Multicast > MLD
Snooping-proxy > Filtering > Filtering Profile screen.
Apply Click Apply to save your changes to the Switchs run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the Save link on the top navigation
panel to save your changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to reset the fields to your previous configuration.