17
Programming Question Table
Q # QUESTION DEFAULT
Q-1
Select RF sensor # (01-48)
Q-1 SUB-QUESTIONS
Select RF sensor (#) type (00) unused
Select RF sensor (#) equipment type
Varies by RF sensor type
(Only shown for some sensor types)
Select RF sensor (#) equipment code (0000) other
Enter RF sensor (#) other equipment code (0-9999) 0 (Only shown if other is selected)
Enter RF sensor (#) serial number (7 digits) 0000000
Select RF sensor (#) equipment age (0-1) (0) new
Select RF sensor (#) loop number (1-3) Varies with sensor model selected
Select RF sensor (#) dialer delay (0-1) (1) enabled (except for fi re & CO)
Construct RF sensor (#) voice descriptor No default
Select RF sensor (#) reports (0-1) (1) enabled
Select RF sensor (#) supervised (0-1) (1) enabled
Select RF sensor (#) chime (0-5) (0) disabled
Q-2
Select wired sensor # (1-2)
Q-2 SUB-QUESTIONS
Select wired sensor (#) type (00) unused
Select wired sensor (#) equipment type
Varies by wired sensor type
(Only shown for some sensor types)
Enter wired sensor (#) equipment code (0-9999) 0
Select wired sensor (#) equipment age (0-1) (0) new
Select wired sensor (#) normal state (0) not used
Select wired sensor (#) dialer delay (0-1) (1) enabled
Construct wired sensor (#) voice descriptor No default
Select wired sensor (#) reports (0-1) (1) enabled
Select wired sensor (#) chime (0-5) (0) disabled
Q-3
Select fob # (1-8)
Q-3 SUB-QUESTIONS
Select fob (#) used (0-1) (0) unused
Select fob (#) equipment code (0000) (0000) other
Enter fob (#) other equipment code (0-9999) 0 (Only shown if other is selected)
Enter fob (#) serial number (7 digits) 0000000
Select fob (#) equipment age (0-1) (0) new
Select fob (#) emergency key (0-4) (0) disabled
Select fob (#) key 2 can disarm (0-1) (1) enabled
Construct fob (#) voice descriptor keyfob #
Select fob (#) arm no delay (0-1) (0) disabled
Select fob (#) key 4 output (0-2) (0) disabled
Q-4
Select RF keypad # (1-4)
Q-4 SUB-QUESTIONS
Select RF keypad (#) used (0-1) (0) unused
Select RF keypad (#) equipment code (0000) other
Enter RF keypad (#) other equipment code (0-9999) 0 (Only shown if other is selected)
Enter RF keypad (#) serial number (7 digits) 0000000
Select RF keypad (#) equipment age (0-1) (0) new
Select RF keypad (#) emergency keys (0-1) (1) enabled
Construct RF keypad (#) voice descriptor keypad #
Q-5
Enter exit delay, in seconds (45-120) 60 seconds
Q-6
Enter entry delay 1, in seconds (30-240) 30 seconds
Q-7
Enter entry delay 2, in seconds (30-240) 45 seconds
Q-8
Select dialer (0-1) (0) disabled
Q-9
Enter dialing prefi x (0-4 digits) No default
Q-10
Enter call waiting disable code (0-6 digits) No default
Q-11
Enter CS #1 phone number (0-25 digits) No default
Q-12
Enter CS #1 account number (4 digits) No default
Q-13
Select 2-way voice (0-2) (1) stay on line
Q-14
Select silent panic/burglary listen only (0-1) (1) enabled
Q-15
Select dialing type (0-1) (0) touch tone
Q-16
Select police emergency key (0-2) (1) audible
Q-17
Select fi re emergency key (0-1) (1) audible
Q-18
Select emergency key (0-1) (1) audible
Q-19
Select quick arming (0-1) (1) enabled
Q-20
Select swinger shutdown count (1-6) (2) two trips
Q-21
Select siren supervision time (0-3) (0) disabled
Q-22
Enter CS lack of usage notifi cation time (0-255) 7 Days
Q-23
Enter radio modem network failure time (0-255) 30 minutes
Q-24
Select radio modem network failure causes trouble (0-1) (1) enabled
Q-25
Select radio modem network failure reports (0-1) (1) enabled
Q-26
Select auto stay (0-1) (1) enabled
Q-27
Select exit delay restart (0-1) (1) enabled
Q # QUESTION DEFAULT
Q-28
Select quick exit (0-1) (1) enabled
Q-29
Enter periodic test, in days (0-255) 30 days
Q-31
Enter cancel time, in minutes (5-255) 5 minutes
Q-32
Select cancel display (0-1) (1) enabled
Q-33
Select cross sensor 47-48 (0-1) (0) disabled
Q-34
Enter cross sensor timeout, in seconds (10-120) 10 seconds
Q-35
Select abort window dialer delay (0-2) (1) 30 seconds
Q-36
Select burglary bell cutoff (0-4) (0) 4 minutes
Q-37
Select fi re bell cutoff (0-4) (0) 4 minutes
Q-38
Enter time to detect AC loss, in minutes (0-30) 10 minutes
Q-39
Select random AC loss report time (0-1) (1) enabled
Q-40
Enter CS #2 phone number (0-25 digits) No default
Q-41
Enter CS #2 account number (4 digits) No default
Q-42
Select remote control phone (0-3) (3) data and voice
Q-43
Enter installer code (4 digits) 1561
Q-44
Select lock installer programming (0-2) (0) disabled
Q-45
Select lock default programming (0-2) (0) default all
Q-46
Select trouble doesn’t sound at night (0-1)
(1) enabled
Q-47
Select trouble resound after holdoff (0-7) (0) disabled
Q-48
Enter download csid (6 digits) 000000
Q-49
Select programming mode entry reports to CS (0-1) (0) disabled
Q-50
Select trouble reports to CS (0-1) (1) enabled
Q-51
Select manual bypass reports to CS (0-1) (0) disabled
Q-52
Select AC loss reports to CS (0-1) (1) enabled
Q-53
Select system low battery reports to CS (0-1) (1) enabled
Q-54
Select RF low battery reports to CS (0-1) (1) enabled
Q-55
Select opening reports to CS (0-1) (0) disabled
Q-56
Select closing reports to CS (0-1) (0) disabled
Q-57
Select alarm restore reports to CS (0-1) (0) disabled
Q-58
Select trouble restore reports to CS (0-1) (1) enabled
Q-59
Select bypass restores reports to CS (0-1) (0) disabled
Q-60
Select AC restore reports to CS (0-1) (1) enabled
Q-61
Select system low battery restore reports to CS (0-1) (1) enabled
Q-62
Select RF low battery restores reports to CS (0-1) (1) enabled
Q-63
Select phone fail detect (0-1) (0) disabled
Q-64
Select smart test reports (0-1) (0) disabled
Q-65
Select RF jam causes trouble (0-1) (0) disabled
Q-66
Select daylight saving (0-1) (1) enabled
Q-67
Select daylight saving start month (01-12) (03) March
Q-68
Select daylight saving start Sunday (1-7) (2) 2nd
Q-69
Select daylight saving end month (01-12) (11) November
Q-70
Select daylight saving end Sunday (1-7) (1) 1st
Q-71
Select system tamper causes trouble (0-1) (1) enabled
Q-72
Select quick bypass (0-1) (0) disabled
Q-73
Select disarming keyfob after alarm (alert) (0-1) (0) disabled
Q-74
Select keyfob arm / disarm confi rmation (0-1) (0) disabled
Q-75
Select auto unbypass for manual bypass (0-1) (1) enabled
Q-76
Select force bypass reports (0-1) (0) disabled
Q-77
Select event log (0-3) (3) all events
Q-78
Select output (00-10) (11) follows internal sounder alarm
Q-79
Select Z-Wave feature (0-3) (1) disabled but visible
Q-80
Select Z-Wave switches feature (0-1) (0) disabled
Q-81
Select Z-Wave thermostats feature (0-1) (0) disabled
Q-82
Select Z-Wave door locks feature (0-1) (0) disabled
Q-83
Select temperature display units (0-1) (0) degrees Fahrenheit
Q-84
Select services require master code (0-1) (0) disabled
Q-85
Select master user access to zwave toolbox (0-1) (0) disabled
Q-86
Select disable siren after two-way audio (0-1) (0) disabled
Q-87
Select keyfob/remote arming mode on system not
ready (0-2)
(0) auto-bypass with zone
participation on restore
Q-88
Select siren mode (0-1) (0) sound for burglary and fi re/CO
‡ Default set for SIA CP-01 compliance
For UL985 Installations, this feature must be disabled