8.3.3. SMS Sending Input Parameters
Telephone number for SMS Function No.: -
The telephone number to which an SMS is sent upon SMS input activation. If
blank, the function is off.
Setting options: 0-16 characters (0-9,*,#,+)
Default setting: blank
SMS text Function No.: -
The SMS text to be sent to the preset telephone number. If the SMS text is blank,
an empty SMS is sent.
Setting options: 0-40 characters
Default setting: blank
Send if activated longer than [ms] Function No.: -
Set the SMS activation time necessary for SMS sending. This parameter
prevents SMS sending in the event of short-time activation. If a "0" is selected,
SMS is sent immediately upon the input activation.
Setting options: 0-25500 ms
Setting step: 100 ms
Default setting: 0 ms
Timeout after sending [s] Function No.: -
Set the Time of inactivity after SMS sending. During this timeout no SMS is sent
even if the SMS input gets activated. This prevents sending multiple SMS units in
the case of repeated activation of the input.
Setting options: 0-2550 s
Setting step: 10 s
Default setting: 0 s
8.3.4. GSM & SIM Parameters
GSM operator lock Function No.: -
Provider blocking is set by manufacturer in EasyGate. If EasyGate is blocked to a
GSM provider, no other GSM provider's SIM card can be used. If an
unacceptable SIM card is used, the GSM modules does not registered to GSM
and the GSM network LED flashes quickly on the EasyGate panel.
CLIR - incognito Function No.: 41
Sets the calling line identification restriction (CLIR) for outgoing calls from
EasyGate. Attention, before enabling it is necessary to activate this feature by
GSM operator, otherwise outgoing calls can be rejected by GSM network.
Setting options:
-According to provider - depending on how the function is selected
in the GSM network
-Activation - ID is not sent.
-Suppression - ID is always sent.
Default setting: According to provider

Other manuals for 2N EasyGate

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2N EasyGate and is the answer not in the manual?

2N EasyGate Specifications

General IconGeneral
Device typeCellular network gateway
Market positioningBusiness
Data networkGPRS, GSM
GSM bands supported850, 900, 1800, 1900 MHz
GPRS multislot class10
Input voltage12 V
Operating temperature (T-T)0 - 45 °C
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)170 x 130 x 45 mm