EasyManua.ls Logo

2N IP Solo - Overvoltage Protection; Protection Recommendations

2N IP Solo
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual 2N® IP Solo
50 / 74
2.3.1 Overvoltage Protection
Recommendations for Additional Overvoltage Protection Installation
If running:
a) outside a building,
b) on/in an outer wall or roof,
the 2N device wiring may be exposed to atmospheric effects resulting in overvoltage that may
subsequently damage any devices installed outside the building, on its outer wall or roof.
Overvoltage may damage devices connected to these wires and installed inside the building as
well. Therefore, we recommend that additional surge protectors be installed on all the wires
leading outside buildings, on outer walls or roofs, namely:
a) as close as possible to the device installed outside the building or on its outer wall/roof,
b) as close as possible to the point where the wires leave the building.
OVP = overvoltage
protection

Related product manuals