Operation
Section 1
Page 49
AC Line Test
RED to RING
BLACK to TIP
GREEN to GROUNDED SHIELD
Hookup:
R
B
G
Note: This chart shows the tests in order as they run for
each of three testline types in a typical AC Line Test. The
test and diagnostics may differ for your application.
GROUND
*See 3M 1020B Operators Manual for instructions.
AC LINE TEST
VOLTAGE
CURRENT
LOSS
NOISE
PWR INFLUENCE
BALANCE
DIAGNOSIS
END
OF
TEST
3M 1020
MILLIWATT STEP TONE
LOSS
LOSS
NOISE
COMMAND*
SLOPE
DIAGNOSIS
On some floating-tip
switches such as
#5 ESS, ground
resistance cannot
be measured as the
switch operates on
a floating ground.
Available in 900-T-Series test sets only:
NO STORE RESULTS? YES
EDIT TITLE
GO TO STEP
TONE OR END
END
OF
TEST
DIAGNOSIS
YES
NO
GO TO
DC LINE
TEST