Specifications
Section 3
Page 69
C. Outputs
Tones Frequency Level Impedance
Identification: 577.5 Hz 6V PK to PK 100 ohms
(Current limited
to 6 mA)
Precision Tones: 1004 +
1 Hz 0 dBm + 0.2 dB 600 Ohm
Harmonic distortion: <45 dB (up to 10th harmonic)
D. Environment
Operation Storage
Temperature: 0° to +140° F –40° to 165° F
–18° to 60° C –40° to 74° C
Humidity: 0 to 100% 0 to 100%
(condensing) (condensing)
Altitude: 0 to 15,000 ft 0 to 40,000 ft
0 to 5000 m 0 to 12000 m
Shock: Can withstand a drop onto a wood surface
from a distance of four ft (1.25 m)
E. Dimensions
Height 7.0 in/ 18 cm
Width 10.5 in/ 27 cm
Depth 7.5 in/ 19 cm
Weight 7.5 lbs/ 3.4 kg
Cord length 5 ft/ 1.5 m
F. Battery Power
The operating time between battery change-out or charges depends
on temperature of set and operation modes used.
For non-rechargeable batteries typical operating time is about 200
hours between battery change-out.
For rechargeable batteries typical operating time is about 80 hours
between charges.