16
3M™ Battery Pack TR-830 can provide approximately 750 full charge/discharge cycle equivalents while maintaining 80% of
its original capacity, when used under recommended conditions and during its rst year of service. Normal use of the battery
and natural aging of battery cells will gradually decrease the battery’s available capacity. For additional information on
battery use and optimization see the Versao™ TR-830 Chargers and Battery Packs User Instructions and 3M Technical Data
Bulletin #223 3M™ Versao™ PAPR Battery Maintenance.
Do not store battery packs where temperatures may exceed 122°F (50°C).
Disposal
W WARNING
Dispose of lithium-ion battery packs according to local environmental regulations. Do not dispose of in standard waste
bins, in a re or send for incineration. Failure to properly dispose of battery packs may lead to environmental
contamination, re or explosion and may result in serious injury or death.
In the United States and Canada, 3M participates in the Call2Recycle program which provides for 3M™ PAPR Batteries to be
dropped off (free of charge) at participating recycling collection sites. Please dispose of batteries according to federal, state,
provincial and local regulations. Contact the Call2Recycle Hotline at 1-877-273-2925 or go to their website,
www.call2recycle.org, for drop off site locations.
Used lter/cartridges should be disposed of based on the contaminants collected on it and according to local environmental
regulations.
The motor/blower and charger contain electronic components. Dispose of according to local and government regulations.
TECHNICAL SPECIFICATIONS
Consult the 3M™ Versao™ Powered Air Purifying Respirator TR-800 Technical Specications sheet for additional
specications.
Airow Approx. 6.7 cfm (190 lpm): Standard ow
Approx. 7.2 cfm (205 lpm): Medium ow
Approx. 7.8 cfm (220 lpm): High ow
Intrinsic Safety
Exia Division 1: IS Class I, II, III; Division 1
(Includes Division 2); Groups C, D, E, F, G; T4
Ex ia I Ma
Class I, Zone 0, AEx ia IIB; T4
Class I, Zone 0, Ex ia IIB; T4
Zone 20, AEx ia IIIC; T135°C
Zone 20, Ex ia IIIC; T135°C
-20°C ≤ T
a
≤ 55°C
Weight:
TR-800 motor/blower- no battery pack
Standard battery pack- TR-830
High durability belt- TR-626
Easy clean belt- TR-627
Approx. 1.5 lbs (675 grams)
Approx. 1.5 lbs (663 grams)
Approx. 0.9 lbs (425 grams)
Approx. 0.6 lbs (270 grams)
Operating temperature
Operating altitude/elevation range
23°F to 131°F (-5°C to 55°C)
-328 feet to 16404 feet (-100 meters to 5000 meters)
Storage conditions:
Relative humidity
Temperature (daily storage)
Temperature (extended storage)
Optimal temp for battery packs to maintain existing
charge while stored off charger
< 90%
-22°F to 122°F (-30°C to 50°C)
40°F to 95°F (4°C to 35°C)
59°F (15°C)
Battery charging*
* Based on the internal temperature of the battery
Range: 32°F to 104°F (0°C to 40°C)
Optimal: 68°F to 77°F (20°C to 25°C)
Shelf life from date of manufacture when stored in original
packaging and recommended storage conditions:
1. Motor/blower
2. Battery pack
3. Filters and cartridges
1. 5 years*
2. 6 months
3. 5 years
*Run for 5 minutes/year