Chapter 12. Troubleshooting
248 3ware Serial ATA RAID Controller User Guide
Note: This message only applies to the 3ware 9500S controller, which has
removable memory. Other 3ware controller models do not have memory that
can be removed.
Action
Replace the incompatible SO-DIMM with a compatible one.
See Also
For a list of SODIMMs compatible with the 9500S, see
http://www.3ware.com/KB/article.aspx?id=11748.
0038 SO-DIMM not detected
Event Type
Error
Cause
The 3ware 9500S RAID controller is inoperable due to missing SO-DIMM
memory.
Note: This message only applies to the 3ware 9500S controller, which has
removable memory. Other 3ware controller models do not have memory that
can be removed.
Action
Install a compatible SO-DIMM on the controller.
See Also
For a list of SODIMMs compatible with the 9500S, see
http://www.3ware.com/KB/article.aspx?id=11748.
0039 Buffer ECC error corrected
Event Type
Warning
Cause
The controller has detected and corrected a memory ECC error.