Installation
44 Instruction manual BFC
3
is
10. Read the pressure from the meter at the moment when the appliance
switches from
PRE PURGE
to
PRESSURE SWITCH
. At this point, the
appliance's display will show:
11. Check whether the measured value matches the value from the
table (3.4.3 "
Gas data").
Note
If the message
PRESSURE SWITCH
does not appear, there is a fault. This
must be resolved first by a qualified service engineer.
12. Shut off the gas supply.
13. Disconnect the pressure gauge.
14. Put the two black caps back on the pressure switch.
15. Replace the covers.
ON Ê Ê Ê
13:45 Thursday 63ÉC
Tset 65ÉC
PRESSURE SWITCH
a