50
CURRENT FAULT
DESCRIPTION/ACTION DISPLAY
         
        


         


       
       
       


           


CHANGE BACK
ADVANCED
Blocked Exhaust
Fault occurred 2 mins ago
The exhaust is blocked or
restricted. Ensure
condensate hose is draining.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)
FAULT HISTORY
DESCRIPTION/ACTION DISPLAY
         
        


            




1: Blocked Air Intake (A7)
51 mins ago
2: Blocked Exhaust (A8)
54 mins ago
3: Low Gas Pressure (A6)
57 mins ago
4: Blower Prover Failure (AC)
VIEW BACK HELP
Fault History
FAULT OCCURRENCE
DESCRIPTION/ACTION DISPLAY
         
        


          
         

NOTE:          

           

Ignition Failure 10
ECO 0
Low Gas Pressure 10
Blocked Intake Air 0
Blocked Exhaust 0
Thermostat Input 4 0
Blower Prover 3
BACK HELP
Fault Occurrence
RESTORE FACTORY DEFAULTS
DESCRIPTION/ACTION DISPLAY


         
       
        

        

YES NO
Restore Factory Defaults
Are you sure you want to
restore the system to factory
defaults?