Read out of Dispenser Details (1.11.x)
Different protocols / manufacturers provide different details on acceptors. For almost all recyclers the
details are copied from the acceptor field.
The Description (Dispenser.Description) field is generated as follows:
The replies to:
• Request Software Revision (241) &
• Request Product Code (244) commands, separated by ‘~’ characters.
Each individual field is truncated to 15 characters, and is omitted if there is no
response to the command, although the ‘~’ character is still inserted.
The 12 character firmware revision, followed a ‘~’ followed by the 32 character device
information.
The phsyicalCashUnit name.
The Dispenser.SerialNumber field is generated as follows: