Milan / Paylink System Manual Issue 1.5 29 January 2020
CONFIDENTIAL
Not to be disclosed without prior written permission from Aardvark Embedded Solutions Ltd
Page 49 of 71
CCNet note processing
Fault Events
There is no specific self test command with CCNet, the acceptor reports faults in response to a poll.
When the protocol handler completes its initialisation, the first idle response is reported as
IMHEI_NOTE_NOW_OK.
When a FAILURE response to a status poll is received, this is reported as an
IMHEI_NOTE_UNIT_REPORTED_FAULT event. A failure status is expected to be continually reported by
the acceptor until it is cleared. When the acceptor again reports IDLING, then an IMHEI_NOTE_NOW_OK
event is reported.
Other “non normal” responses to a status poll are reported as events as they are receive according to
the table below.
In a similar way to the action for faults, OUTPUT_FIXED is reported when events that translate to
OUTPUT_PROBLEM are cleared.
Most status values are part of the normal running of the system, the following statuses are regardless
as reporting unusual / fault events and are reported through the event system.
Status Value
Name
Event Classification
RawEvent
0x1C 0x68
REJECTING
INHIBITED
0x68
0x1C nn
REJECTING
REJECTED
nn
0x41
DROP CASSETTE FULL
OUTPUT_PROBLEM
0x41
0x42
DROP CASSETTE REMOVED
OUTPUT_PROBLEM
0x42
0x43
JAM IN ACCEPTOR
MISREAD
0x43
0x44
JAM IN STACKER
OUTPUT_PROBLEM
0x44
0x45
CHEATED
FRAUD
0x45
0x47 nn
GENERIC BB ERROR
FAULT
nn
0x82 nn
RETURNED
RETURN
nn
0x14
IDLING
Generate an OK_NOW or OUTPUT_FIXED
if in fault / output problem.
0x19
DISABLED