ID-003 note processing
Fault Events
There is no specific self test command with ID-003, the acceptor reports faults in response to a poll.
When the protocol handler completes its initialisation, the first idle response is reported as
IMHEI_NOTE_NOW_OK.
When a FAILURE response to a status poll is received, this is reported as an
IMHEI_NOTE_UNIT_REPORTED_FAULT event. A failure status is expected to be continually reported by
the acceptor until it is cleared. When the acceptor again reports IDLING, then an IMHEI_NOTE_NOW_OK
event is reported.
Other “non normal” responses to a status poll are reported as events as they are receive according to
the table below.
In a similar way to the action for faults, OUTPUT_FIXED is reported when events that translate to
OUTPUT_PROBLEM are cleared.
Status
Value
Name
Event Classification
0x17
REJECTING
REJECTED
0x41
POWER UP WITH BILL IN ACCEPTOR
REJECTED
0x42
POWER UP WITH BILL IN STACKER
REJECTED
0x43
STACKER FULL
OUTPUT_PROBLEM
0x44
STACKER OPEN
OUTPUT_PROBLEM
0x45
JAM IN ACCEPTOR
JAM
0x46
JAM IN STACKER
OUTPUT_PROBLEM
0x47
PAUSE
UNKNOWN
0x48
CHEATED
FRAUD
0x49
FAILURE
- Fault Report
0x4A
COMMUNICATION ERROR
INTERNAL_PROBLEM