Voice over IP (VoIP) Aastra 277xip (OpenPhone 7x IPC)
136
You will not need a licence to install Aastra 277xip (OpenPhone 7x IPC) but you will
require a licence to operate it with the OpenCom 100. Unit licences, enabling the
simultaneous operation of a certain number of Aastra 277xip
(OpenPhone 7x IPC)s, are available.
The licences are activated in the OpenCom 100’s Configurator in the Menu
System: Licences. The system software includes a licence for a demo version for
temporary use (60 days). Please contact your local dealer or Aastra sales
department if you wish to purchase a permanent licence. Licences can be com-
bined. Each licence can be activated only once.
9.6.1 Installation
Installation is done using a setup programme. The Aastra 277xip
(OpenPhone 7x IPC) can also be installed without a user interface. The programme
can then be used via a CTI application (Net-TAPI or OpenCTI).
Start the installation programme Aastra 277xip (OpenPhone 7x IPC) from the
product CD and follow the installation assistant’s instructions.
9.6.2 Configuration
Analogue to the VoIP system telephones, the Aastra 277xip (OpenPhone 7x IPC)
creates multiple IP connections to the OpenCom 100. When you start the pro-
gramme for the first time, the Options dialogue is automatically opened. Here you
must configure the following values:
1. Enter in the VoIP IP Address field the OpenCom 100’s IP address.
2. Enter six hexadecimal-digits into the Device ID field. This device ID is not a
MAC address, so overlapping with existent MAC addresses is possible. The
device ID is configured in the Configurator, on the Telephony: Devices: VoIP
Phones page.
3. Confirm with OK.
Notes
VoIP system telephony requires an active IP connection to a workstation com-
puter. If a Firewall is installed for your workstation computer, you may need to
explicitly allow this connection.