S
2M
Connector Module Configuration
71
7. Reconnect the OpenCom 130 / 150 to the power supply.
8. Configure the S
2M
module in the Configurator of the OpenCom 130 / 150
(refer to Configuration starting on page 76). Check the level 1 status with ref-
erence to the LEDs on the module. None of the LEDs are illuminated before the
S
2M
module has been configured.
9. Pull out the mains plug of the OpenCom 130 / 150 again and close the housing.
10.Reconnect the OpenCom 130 / 150 to the power supply.
5.2 Configuration
The menu item S
2M
appears in the Configurator, menu Telephony: Ports after
installation of the S
2M
module. Configure the port in the input mask of this menu
item. Further information on this can be found in the online help.
LED Display
LED Meaning
1 (green) Synchronous (= ok)
2 (green) Blue alarm
3 (yellow) Remote alarm or out of sync
(yellow alarm)
4 (red) Loss of signal (red alarm)