6.0.0 TECHNICAL DATA
6.1.0 POWER UNIT
System connection
For 3 x 400 V~ 50 Hz with L1-L2-L3-N-PE; Housing only
for standardised service connection with fusing and
residual-current circuit-breaker. The main switch must
have a minimum contact gap of 3 mm.
Control voltage
Extra-low voltage 5 V= and 12 V=
System cable
Typically 5 x 2.5 mm²
Light connection
For 2- (3-) pole connection of the 230 V incandescent
lamp(s); max. 100 W
Heater connection
3 x 400 V~ 5-pole, up to max. 3 kW depending on the
heater output, and/or 14 A per phase
Thermal release
Integrated into the heater sensor as overtemperature
protection; release temperature 139 °C
Temperature sensor
2-pole; semi-conductor sensor -9 ° to 140 °C
Power input
Heater: max. 3 x 3 kW (heater)
Light: max. 100 W
Ambient conditions
0 °C to max. 50 °C, max. 95 % rel. humidity, not
condensating!
Housing
IP54; CAT2
Fixing
Screwing-on by means of 4 M3 fixing holes
Dimensions: L x W x H
250 x 165 x 55 mm
Weight
950 g