Smile Tina
Emergency stop with indication

Questions and Answers

  • R
    russelljenniferAug 9, 2025
    How to fix red lights on ABB Control Unit?
    • W
      wilsonkyleAug 10, 2025
      If the ABB Control Unit shows red lights, it could be due to the E-stop button being down. To resolve this, reset the button by turning it clockwise and pulling it upward. Another cause could be the absence of a 24 VDC input to pin-2 (no dynamic signal). In this case, check if there is 24 VDC to input (pin- 2). If yes, inspect the cable or the unit before it, and fix any issues.
  • H
    Heather ChristianAug 16, 2025
    What to do if ABB 30-050-02 has no lights?
    • C
      cameronmosesAug 16, 2025
      If your ABB Control Unit has no lights, it is likely due to a loss of power supply. You should check the 24 VDC / 0 VDC power supply.
  • M
    Maria ThompsonAug 25, 2025
    Why ABB 30-050-02 Control Unit lights are green but no dynamic output?
    • E
      Eric HigginsAug 25, 2025
      If the ABB Control Unit displays green lights but no dynamic output is detected, the issue might be a defected dynamic signal input to the unit (asymmetric pulses). Check the dynamic input or the unit before it.
  • D
    Denise SweeneySep 1, 2025
    What does it mean if ABB Control Unit lights are weak or red and green at the same time?
    • I
      iortizSep 1, 2025
      If the ABB Control Unit exhibits weak lights or displays both red and green lights simultaneously, it indicates that the unit is defect. The unit needs to be replaced.

Summary

2 Overview

Safety Regulations

Warnings and requirements for safe installation and use of the device.

4 Installation and Maintenance

Installation Precautions

Steps for mounting Smile Tina and connecting it.

Maintenance Guidelines

Guidelines for regular testing and warnings against product repair.

Safety Function Testing

Procedure to verify the safety unit's functionality.

Troubleshooting Guide

Table detailing LED indicators, fault causes, and solutions.

5 Operation

7 Technical Data

Safety and Harmonized Standards

List of relevant safety standards and directives the product complies with.

8 EC Declaration of Conformity

ABB 30-050-02 Specifications

General IconGeneral
BrandABB
Model30-050-02
CategoryControl Unit
LanguageEnglish

Related product manuals