EasyManua.ls Logo

ABB A130 - 4 Commissioning Procedures; 4.1 Oil Supply Management

ABB A130
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / A130-M.. - A145-M..
4 Commissioning / 4.1 Oil supply
© Copyright 2021 ABB. All rights reserved. HZTL4031_EN Rev.N March 2021
4 Commissioning
4.1 Oil supply
4.1.1 Introduction
In all operating states, a functioning and carefully executed oil supply is an important pre-
requisite for trouble-free operation of the turbocharger.
The lubrication of the turbocharger is usually carried out with oil from the engine oil circula-
tion.
u Comply with the enginebuilder's specifications regarding the selection of lubricating oil
and the oil change intervals.
4.1.2 Pre-lubrication
Pre-lubrication must be carried out as follows:
u Switch on the oil pump.
u Build up oil pressure.
u Do not exceed a pre-lubrication time of 2minutes.
u Start the engine.
u Let the oil pump run until the pump driven by the engine generates sufficient pressure.
4.1.3 Oil filtering
Filtering the lubricating oil with a filter mesh width of 0.034mm is sufficient for this tur-
bocharger.
4.1.4 Oil pressure
Comply precisely with the oil pressure before the turbocharger for trouble-free operation.
The admissible values are specified in chapter Monitoring operation 49.
Page 44 / 149

Table of Contents