242 ACH580 E-Clipse bypass and packaged drive user manual
Technical data
ACH580-PxR-052A-6
3
52 50 R5 Class T 80A N/A N/A
ACH580-PxR-062A-6 62 60 R5 Class T 80A N/A N/A
ACH580-PxR-077A-6 77 75 R5 Class T 100A N/A N/A
ACH580-PxR-099A-6 99 100 R7 Class T 150A N/A N/A
ACH580-PxR-125A-6 125 125 R7 Class T 175A N/A N/A
ACH580-PxR-144A-6 144 150 R8 Class T 200A N/A N/A
ACH580-PxR-180A-4 180 150 R2 Class T 300A N/A N/A
ACH580-PxR-240A-4 240 200 R2 Class T 350A Class J
or RK1
400A Max
1) “PxR” represents both PCR and PDR.
2) PCR is rated 600Y/347V unless otherwise specified. For use on a solidly grounded Wye source only.
3) PCR supports Delta network configuration.
575 Volt
Nominal Output
Range
Base
Drive
Frame
Size
Internal Drive
Fuse Rating
External Fuse for
Disconnect Option
Type Code
1, 2
Drive
Current
Package
Power
A HP Class
Current
Rating
Class
Max Current
Rating