244 ACH580 E-Clipse bypass and packaged drive user manual
Technical data
Dimensions: ACH580-PxR UL (NEMA) Type 12
See page 243 for mounting dimension details and additional free space
recommendations.
Note: Keep a minimum of 50 mm (2 in.) of free space on each side and 200 mm
(8 in.) of free space above and below all units from non-heat producing sources.
Double these distances from heat producing sources.
Frame
Height (H) Width (W) Depth (D) Weight
Dimensional
Drawings
in mm in mm in mm lb kg
Px12-1 26.50 673 6.50 164 12.40 315 18.2 8.2 3AXD50000220953
Px12-2 30.22 768 6.50 164 12.64 321 22.0 10.0 3AXD50000221912
Px12-3 36.51 927 8.39 213 13.22 335 39.0 17.7 3AXD50000222834
Px12-4 42.50 1079 8.39 213 14.26 362 60.0 27.2 3AXD50000222674
PxB12-1 33.16 842 17.63 447 13.90 353 77.0 35.0 3AXD50000236305
PxB12-2 40.60 1030 20.50 521 15.30 388 122.0 55.3 3AXD50000236619
PxB12-3 54.17 1376 28.24 717 19.04 483 393.0 178.3 3AXD50000236718
Px12-1 to Px12-4
PxB12-1 to PxB12-2
W
H
D
W
H
D
PxB12-3
W
H
D