28 Start-up and controls
Editing pump parameters
The parameters 6001...6019 are user adjustable parameters to control the pump
operation. The below steps explain the editing of inverter start voltage and inverter reset
time. Similarly, edit the other pump parameters in this group.
Step Description Keys Control panel
Setting inverter starting voltage
1 Select 60 PUMP CONTROL
with the UP/DOWN keys and
press SEL.
2 Select parameter 6003
START DC VOLT with the
UP/DOWN keys. Press EDIT
to change the parameter
value.
You can edit the minimum DC
voltage to start the inverter.
Note: If you change this value
while the inverter is running,
the changed value is effective
only during the next start.
3 Press the UP/DOWN keys to
change the parameter value
and press SAVE to store the
modified value or press
CANCEL to leave the set
mode. Any modifications not
saved are cancelled.
Press EXIT to return to the
listing of parameter groups,
and again to return to the
main menu.
REM
PAR GROUPS
60 PUMP CONTROL
98 OPTIONS
99 START-UP DATA
60
EXIT
SEL
00:00
01 OPERATING DATA
61 FLOW CALCULATION
REM
PARAMETERS
6004 PV CELL MIN VOLT
6001 AUTO/MANUAL SEL
6002 MANUAL START CMD
6003 START DC VOLT
250 V
EXIT
EDIT
00:00
REM
PAR EDIT
6003 START DC VOLT
250 V
CANCEL
SAVE
00:00