Actual signals and parameters 37
7
Actual signals and parameters
About this chapter
This chapter describes the actual signals and user-adjustable parameters of the MPPT
function specific to the solar pump inverter. Refer these parameters in addition to the
actual signals and parameters described in the ACS355 User’s manual
(3AUA0000066143 [English]).
Actual signals
Actual signals
No. Name/Value Description FbEq
01 OPERATING DATA
Basic signals for monitoring the solar pump
inverter (read-only). The inverter sets the values
based on measurements or calculations.
0182 PUMP RUN HOUR Shows the actual run time of the pump in hours.
Note: You can reset the counter to zero when the
control panel is in parameter mode. Non-zero
values are not accepted.
To reset the counter, press the UP/DOWN
keys simultaneously.
1 = 1 h
0183 CALCULATED FLOW Shows the calculated flow rate of water in cubic
meter per hour. The calculation is based on the
correction factor defined in 6124 FLOW CAL
GAIN.
100 =
1m³/h
0184 TODAY FLOW Shows the measured flow of current day in cubic
meter.
Note: You can reset this value using 6131 RESET
FLOW.
10 = 1 m³