62 ACS510 User’s Manual
Start-Up
4210 SET POINT SEL 0…2, 8…17, 19, 20 1 1 9
4211
INTERNAL SETPNT Unit and scale defined by par. 4206 and
4207
0.0% 40.0%
4212
SETPOINT MIN -500.0%…500.0% 0.1% 0.0%
4213 SETPOINT MAX -500.0%…500.0% 0.1% 100.0%
4214
FBK SEL 1…13 1 1
4215 FBK MULTIPLIER -32.768…32.767 (0 = NOT USED) 0.001 0.000
4216
ACT1 INPUT 1…7 1 2 9
4217
ACT2 INPUT 1…7 1 2 9
4218 ACT1 MINIMUM -1000…1000% 1% 0%
4219
ACT1 MAXIMUM -1000…1000% 1% 100%
4220
ACT2 MINIMUM -1000…1000% 1% 0%
4221 ACT2 MAXIMUM -1000…1000% 1% 100%
4228
ACTIVATE -6…8 1 0
4229
OFFSET 0.0…100.0% 0.1% 0.0%
4230 TRIM MODE 0…3 1 0
4231
TRIM SCALE -100.0%…100.0% 0.1% 0.0%
4232
CORRECTION SRC 1…2 1 1 (PID2 REF)
Group 51: Ext Comm Module
5101
FBA TYPE --0
5102 …
5126
FB PAR 2…26 0...65535 1 0
5127
FBA PAR REFRESH 0 = done, 1 = refresh 1 0 9
5128 FILE CPI FW REV 0...0xFFFF (hex) 1 0
5129
FILE CONFIG ID 0...0xFFFF (hex) 1 0
5130
FILE CONFIG REV 0...0xFFFF (hex) 1 0
5131 FBA STATUS 0…6 1 0
5132
FBA CPI FW REV 0...0xFFFF (hex) 1 0
5133
FBA APPL FW REV 0...0xFFFF (hex) 1 0
Group 53: EFB Protocol
5301
EFB PROTOCOL ID 0...0xFFFF 1 0
5302
EFB STATION ID 0…65535 1 1 9
5303
EFB BAUD RATE 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 76.8
kbits/s
- 9.6 kbits/s
5304
EFB PARITY 0 = 8 NONE 1, 1 = 8 NONE2, 2 = 8 EVEN 1,
3 = 8
ODD 1
0
5305
EFB CTRL PROFILE 0 = ABB DRV LIM, 1 = DCU PROFILE,
2 =
ABB DRV FULL
10 (ABB DRV LIM)
5306
EFB OK MESSAGES 0…65535 1 0
5307
EFB CRC ERRORS 0…65535 1 0
5308
EFB UART ERRORS 0…65535 1 0
5309
EFB STATUS 0…7 1 0 (IDLE)
5310
EFB PAR 10 0…65535 1 0 (NOT SEL)
5311
EFB PAR 11 0…65535 1 0 (NOT SEL)
5312
EFB PAR 12 0…65535 1 0 (NOT SEL)
5313
EFB PAR 13 0…65535 1 0 (NOT SEL)
Code Name Range Resolution Default User S