Frame
size
Output ratingsMax.
cur-
rent
Nom-
inal
In
Drive
Type
ACS560
Heavy-duty useLight overload
use
Nominal use
P
Hd
I
Hd
(Con-
tinu-
ous)
P
Ld
I
Ld
(Con-
tinu-
ous)
P
N
I
N
I
max
I
1N
HpkWAHpkWAHpkWAAA
R8150110206180132234180132246350246246A-4
R8180132
246
1)
215160278215160293418293293A-4
1)
Continuous current when its used in heavy duty applications, allows 130% of IHd for 1 minute every 10
minutes at 40 °C.
Fuses (IEC)
uR and aR fuse
uR and aRInput cur-
rent
Minimum
short cir-
cuit cur-
rent
1)
Drive type
ACS560
IEC
60269
size
Bussmann
designation
type
Rated
voltage
I
2
tRated
current
I
N
VA
2
sAAA
3 phases U
N
= 400 V (380...480 V)
00170M2694690125254.24802A6-4
00170M2694690125255.34803A3-4
00170M2695690275326.48004A0-4
00170M2695690275329.08005A6-4
00170M26966904904011.512807A2-4
00170M269669010004015.012809A4-4
00170M269769018005020.220012A6-4
00170M269869036006327.2256017A-4
00170M269969014508040.0400025A-4
000170M156569014506332.0170033A-4
000170M156569025506338.0170039A-4
000170M156669046508045.0280046A-4
1170M1567690850010062.0380062A-4
000170M15686901600012573.0480073A-4
1170M15696901500016088.0480088A-4
1170M381569028500200106.0700106A-4
1170M381669046500250145.01000145A-4
1170M381769068500315169.01280169A-4
1170M3818690105000350206.01520206A-4