For information on reforming the capacitors, see
Converter module capacitor
reforming instructions
(3BFE64059629 [English]).
■
Select the power cables
Size the power cables according to local regulations to carry the nominal current
given on the type designation label of your drive. See Ratings (page 127).
■
Ensure the cooling
The maximum ambient temperature without derating is:
• 50 °C (+122 °F) for R0...R2 frames
• 40 °C (+104 °F) for R3...R8 frames
No condensation or frost is allowed. For more information on the ambient
temperature, see the hardware manual.
■
Protect the drive and input power cable
If you use gG fuses, make sure that the operating time of the fuse is below 0.5
seconds. Follow the local regulations.
4 EN - Quick installation and start-up guide
EN
HI