3. Connect the motor cable as follows:
If the power cable is temporarily removed from the grounding shelf, connect the
motor and input power cables except the 360° grounding, and then reinstall the
grounding shelf.
• Ground the shield 360° by tightening the clamp of the power cable grounding
shelf onto the stripped part of the cable (4a).
• Connect the twisted shield of the cable to the grounding terminal (4b).
• Connect the phase conductors of the cable to the T1/U, T2/V and T3/W
terminals.
• Tighten the screws to the torque given below:
R4R3Frame size
lbf·ftN·mlbf·ftN·m
3.04.01.8…3.32.5…4.5T1/U. T2/V. T3/W.
Notes:
• The screws are of different length. Install them at correct locations.
• After reinstalling the grounding shelf, you can make the 360° grounding for
the cables.
Input power cable
4. Prepare the ends of the cable as illustrated in the figure.
16 EN - Quick installation and start-up guide
EN