ABB ACS560 - Drive configuration and programming

ABB ACS560
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2
4
6
3
5
7
Start mode Automatic, constant time, Fast1
Stop mode Coast, Ramp2
Acceleration time - Time for speed to change from zero to the speed defined by
parameter.
3
Deceleration time - Time for speed to change from the speed defined by parameter
to zero.
4
Maximum frequency/ Speed - Maximum allowed frequency/speed.5
Maximum current - Maximum allowed current.6
Minimum frequency/ Speed - Minimum allowed frequency/speed.7
Selected start mode is Automatic.
1 2
1) Automatic - Default start mode. Guarantees optimal motor start in most cases.
It includes the flying start function (starting into a rotating motor) and the auto-
matic restart function. The drive motor control program identifies the flux as well
as the mechanical state of the motor and starts the motor instantly under all
conditions.
1
2) Constant - Enables constant pre-magnetizing time (the motor start is synchron-
ized with the release of a mechanical brake).
2
3) Fast - The pre-magnetizing time is determined automatically, being typically
200 ms to 2 s depending on motor size. This mode does not have a shortcut icon.
3
Selected stop mode is Coast.
EN - Quick installation and start-up guide 39