DefaultUnitRange/ListNameIndex
NameBitNameBitNameBit
User bit 112Switch-on
inhibited
6Ready to
switch ON
0
User bit 213Warning7Ready run1
User bit 314At set point8Ready ref2
Reserved15Remote9Tripped3
Above limit10Off 2 inact-
ive
4
User bit 011Off 3 inact-
ive
5
0b0000-0b0000...0b1111Drive status word 106.16
NameBitNameBitNameBit
Ext1 active10Started5Enabled0
Ext2 active11Modulating6Inhibited1
Reserved12Limiting7DC charged2
Start re-
quest
13Local con-
trol
8Ready to
start
3
Running14Network
control
9Following
reference
4
Reserved15
0b0000-0b0000...0b111Drive status word 206.17
NameBitNameBitNameBit
Reserved11…12Safe refer-
ence active
5Identifica-
tion run
done
0
Start delay
active
13Last speed
active
6Magnetized1
Reserved14...15Reserved7...8Torque con-
trol
2
Jogging act-
ive
9Speed con-
trol
3
Above limit10Reserved4