Removing drive from the DIN installation rail (frames R0...R2 only)
To remove the drive, open the locking part using a flat-head screwdriver.
Installing a drive with screws (frames R0...R8)
All drives of frames R0...R8 can be installed on a wall with screws. See the required
screw sizes in below mounting dimensions table. See also Dimensions, weights
and free space requirements (page 132)
WARNING!
The drive module (frames R6...R8) is heavy (45 to 70 kg). Consider the
following:
Use a suitable lifting device.
Do not lift the module manually.
Make sure that the wall and the fixing devices can carry the weight. See
data in the table below.
1. Mark the mounting hole locations using the mounting template included in
the package.
Mounting dimensionsMounting template
R8R7R6R5R4R3R2R1R0Frames
M8M6M5Screws
(mm)
1
658583531581619473191a
701623571612-b
2632452131601487550
-75d
20075e
70.055.045.028.023.014.867.544.574.47Weight
(kg)
2. Drill the mounting holes.
3. Tighten the screws into the mounting holes.
4. Position the drive onto the screws on the wall.
5. Tighten the mounting screws.
6 EN - Quick installation and start-up guide