DefaultUnitRange/ListNameIndex
0b0000-0b0000…0b1111Limit word 130.01
NameBitNameBitNameBit
Max freq ref
lim
9Tlim max
speed
5Torq lim0
Min freq ref
lim
10Tlim min
speed
6Reserved1…2
Reserved11...15Max speed
ref lim
7Torq ref
max
3
Min speed
ref lim
8Torq ref min4
0b0000-0b0000…0b1111Torque limit status30.02
NameBitNameBitNameBitNameBit
IGBT
overtem-
perature
11Thermal8Internal
current
4Under-
voltage
0
IGBT
overload
12Max cur-
rent
9Load
angle
5Over-
voltage
1
Re-
served
13…15User cur-
rent
10Motor
pullout
6Minim-
um
torque
2
Thermal
IGBT
11Re-
served
7Maxim-
um
torque
3
*Only one out of bits 0…3, and one out of bits 9…11 can be ON simultaneously.
The bit typically indicates the limit that is exceeded first.
10.00s0...120Current limit monitor time30.09
No action[0]-No action[0], Warn-
ing[1], Fault[2]
Current limit actions30.10
-1500.00rpm-30000.00 … 30000.00Minimum speed30.11
1500.00rpm-30000.00 … 30000.00Maximum speed30.12
-50.00Hz-500.00 … 500.00Minimum frequency30.13
50.00Hz-500.00 … 500.00Maximum frequency30.14
2.92A0.00 … 3.24Maximum current30.17
Parameter listing 81
EN
HI