Operation principle and hardware description   23
Type code
The type code contains information on the specifications and configuration of the 
drive. The first digits from the left are the basic configuration (for example, 
ACS800-01-0006-5). The optional selections are given next and separated by + signs 
(for example, +E202). The main selections are described below. Not all selections are 
available for all drive types. For more information, refer to 
ACS800 Ordering 
Information
 (EN code: 3AFY64556568, available on request).  
Selection Alternatives
Product series ACS800 product series
Type 01 Wall mounted. When no options are selected: IP21, control panel 
CDP 312R, no EMC filter, Standard Control Program, cable connection 
box (cabling from below), brake chopper in frame sizes R2 and R3 
(230/400/500 V units) and in frame size R4 (690 V units), boards 
without coating, one set of English manuals.
U1 Wall mounted (USA). When no options are selected: UL type 1, control 
panel CDP 312R, no EMC filter, US version of the Standard Control 
Program (three-wire start/stop as default setting), US gland/conduit 
box, brake chopper in frame sizes R2 and R3 (230/400/500 V units) 
and in frame size R4 (690 V units), boards without coating, one set of 
English manuals.
Size  Refer to 
IEC data
 (page 106) or 
NEMA data 
(page 119)
Voltage range 
(nominal rating in 
bold) 
2 208/220/230/240 V AC
3380/400/415 V AC
5 380/400/415/440/460/480/500 VAC
7525/575/600/690 VAC 
Option codes (+ codes)
Degree of protection B056 IP55 / UL type 12
Construction C131 Vibration dampers
C132 Marine type approved unit (coated boards included, +C131 required for 
frame sizes R4 to R6 in wall installations, +C131 not required in cabinet 
installations)
Resistor braking D150 Brake chopper
Filter E200 EMC/RFI filter for second environment TN (grounded) system, drive 
category C3 (frame sizes R2…R5)
E202 EMC/RFI filter for first environment TN (grounded) system, drive 
category C2
E210 EMC/RFI filter for second environment TN/IT (grounded/ungrounded) 
system, drive category C3 (frame size R6 only)
Cabling H358 US/UK gland/conduit box
Control panel 0J400 No control panel 
Fieldbus K... Refer to 
ACS800 Ordering Information
 (EN code: 3AFY64556568).
I/O L...
Control program N...
Manual language R...
Safety features Q950 Prevention of unexpected start-up: AGPS board and 3 m connection 
cable (not to be used with option +Q967)
Q967 Safe torque off (STO) function without safety relay: ASTO board and 
3 m connection cable (not to be used with option +Q950)
Specialties P901 Coated boards
P904 Extended warranty