EasyManua.ls Logo

ABB ACS880-17 - Page 329

ABB ACS880-17
604 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters 329
44.03 Brake open torque
reference
Displays the currently active brake open torque. See
parameters 44.09 Brake open torque source and 44.10 Brake
open torque.
This parameter is read-only.
-
-1600.0 … 1600.0% Currently active brake open torque. See par.
46.03
44.06 Brake control
enable
Activates/deactivates (or selects a source that
activates/deactivates) the mechanical brake control logic.
0 = Brake control inactive
1 = Brake control active
Note: This parameter cannot be changed while the drive is
running.
Not selected
Not selected 0. 0
Selected 1. 1
DI1 Digital input DI1 (10.02 DI delayed status, bit 0). 2
DI2 Digital input DI2 (10.02 DI delayed status, bit 1). 3
DI3 Digital input DI3 (10.02 DI delayed status, bit 2). 4
DI4 Digital input DI4 (10.02 DI delayed status, bit 3). 5
DI5 Digital input DI5 (10.02 DI delayed status, bit 4). 6
DI6 Digital input DI6 (10.02 DI delayed status, bit 5). 7
DIO1 Digital input/output DIO1 (11.02 DIO delayed status, bit 0). 10
DIO2 Digital input/output DIO2 (11.02 DIO delayed status, bit 1). 11
Other [bit] Source selection (see Terms and abbreviations on page 114). -
44.07 Brake acknowledge
selection
Activates/deactivates (and selects the source for) brake
open/close status (acknowledgement) supervision.
When a brake control error (unexpected state of the
acknowledgement signal) is detected, the drive reacts as
defined by parameter 44.17 Brake fault function.
0 = Brake closed
1 = Brake open
No
acknowledge
Off 0. 0
On 1. 1
No acknowledge Brake open/closed supervision disabled. 2
DI1 Digital input DI1 (10.02 DI delayed status, bit 0). 3
DI2 Digital input DI2 (10.02 DI delayed status
, bit 1). 4
DI3 Digital input DI3 (10.02 DI delayed status, bit 2). 5
DI4 Digital input DI4 (10.02 DI delayed status, bit 3). 6
DI5 Digital input DI5 (10.02 DI delayed status, bit 4). 7
DI6 Digital input DI6 (10.02 DI delayed status, bit 5). 8
DIO1 Digital input/output DIO1 (11.02 DIO delayed status, bit 0). 11
DIO2 Digital input/output DIO2 (11.02 DIO delayed status, bit 1). 12
Other [bit] Source selection (see Terms and abbreviations on page 114). -
No. Name/Value Description Def/FbEq16