Parameters 379
61.51 Data set 11 data 1
selection
Parameters 61.5161.74 preselect data to be sent in data
sets 11, 13, 15, 17, 19, 21, 23 and 25 to the external
controller.
Parameters 61.10161.124 display the data to be sent to the
external controller. If no data has been preselected, the value
to be sent can be written directly into these parameters.
For example, this parameter preselects the data for word 1 of
data set 11. Parameter 61.101 Data set 11 data 1 value
displays the selected data in integer format. If no data is
preselected, the value to be sent can be written directly into
parameter 61.101.
None
None None. 0
CW 16bit Control Word (16 bits) 1
SW 16bit Status Word (16 bits) 4
Act1 16bit Actual value ACT1 (16 bits) 5
Act2 16bit Actual value ACT2 (16 bits) 6
Other Source selection (see Terms and abbreviations on page 114). -
61.52 Data set 11 data 2
selection
Preselects the data to be sent as word 2 of data set 11 to the
external controller.
See also parameter 61.102 Data set 11 data 2 value.
For the selections, see parameter 61.51 Data set 11 data 1
selection.
None
61.53 Data set 11 data 3
selection
Preselects the data to be sent as word 3 of data set 11 to the
external controller.
See also parameter 61.103 Data set 11 data 3 value.
For the selections, see parameter 61.51 Data set 11 data 1
selection.
None
61.54 Data set 13 data 1
selection
See parameter 61.51 Data set 11 data 1 selection. None
……
61.74 Data set 25 data 3
selection
See parameter 61.51 Data set 11 data 1 selection. None
61.95 Data set 2 data 1
value
Displays (in integer format) the data to be sent to the external
controller as word 1 of data set 2.
If no data has been preselected by 61.45 Data set 2 data 1
selection, the value to be sent can be written directly into this
parameter.
0
0…65535 Data to be sent as word 1 of data set 2.
61.96 Data set 2 data 2
value
Displays (in integer format) the data to be sent to the external
controller as word 2 of data set 2.
If no data has been preselected by 61.46 Data set 2 data 2
selection, the value to be sent can be written directly into this
parameter.
0
0…65535 Data to be sent as word 2 of data set 2.
61.97 Data set 2 data 3
value
Displays (in integer format) the data to be sent to the external
controller as word 3 of data set 2.
If no data has been preselected by 61.47 Data set 2 data 3
selection, the value to be sent can be written directly into this
parameter.
0
0…65535 Data to be sent as word 3 of data set 2.
No. Name/Value Description Def/FbEq16