538 Fault tracing
000B (Asynchronous motors only)
Speed dropped to zero during
ID run.
Contact your local ABB representative.
000C (Permanent magnet motors
only) First acceleration did not
finish within reasonable time.
Contact your local ABB representative.
000D (Permanent magnet motors
only) Second acceleration did
not finish within reasonable
time.
Contact your local ABB representative.
000E…0010 Internal error. Contact your local ABB representative.
FF7E Follower A follower drive has tripped. Check the auxiliary code. Add 2 to the
code to find out the node address of the
faulted drive.
Correct the fault in the follower drive.
FF81 FB A force trip A fault trip command has been
received through fieldbus
adapter A.
Check the fault information provided by
the PLC.
FF82 FB B force trip A fault trip command has been
received through fieldbus
adapter B.
Check the fault information provided by
the PLC.
FF8E EFB force trip A fault trip command has been
received through the
embedded fieldbus interface.
Check the fault information provided by
the Modbus controller.
Code
(hex)
Fault Cause What to do