EasyManua.ls Logo

ABB ACS880+N5350 - Page 68

ABB ACS880+N5350
247 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Modes 9-73AXD50000011888
The Main Status Word (MSW) in the ACS880+N5350 CTDD Drive is different than that of a Standard ACS880. In addition to
the Standard 9 Bits of the Status Word, the following additional Status Bits are available in the ACS880+N5350 CTDD Drive.
Bit Name Value Description
0
Ready to
switch ON
1 Ready to switch ON
0 Not ready to switch ON
1 Ready run
1 Ready to operate
0
OFF1 active
2 Ready ref
1
Operation enabled
0
Operation inhibited
3 Tripped
1
Fault
0
No Fault
4 OFF2 inactive
1
OFF2 inactive
0
OFF2 active
5 OFF3 inactive
1
OFF3 inactive
0
OFF3 active
6
Switch-on
inhibited
1
Switch-on inhibited
0
--
7 Warning
1
Warning active
0
No warning active
8
At setpoint
1
Operating - Actual value equals
reference = is within
tolerance limits (see parameters
46.21 - 46.23)
0
Actual value differs from reference
= is outside tolerance
limits
9
Remote
1
Drive control location: Remote
(EXT1 or EXT2)
0
Drive control location: Local
10
Trickle Current
Active
0
Trickle Current OFF
1 Trickle Current ON
11
De-Ice Mode
Active
0 De-Ice Mode OFF
1 De-Ice Mode ON
12
CTD Run
0 CTD Drive Not Running
1 CTD Drive Running
13
CTD HOLD
0 CTD Autophase OFF
1 CTD Autophase ON
14
User bit 3
- See parameter 06.33 MSW bit 14
sel
15
Reserved

Table of Contents