2TLC172271M0201 Rev.H 25
7 LED indication
The non-safe status LED on Adam shows the status of the Eden sensor and the output status as
follows:
LED on Adam Description Safety circuit
Green Valid Eva within range Closed
Flashing green Valid Eva within range, waiting for reset Open
Flashing red/green Valid Eva within range, no valid in signal Open
Red Valid Eva out of range Open
Fast flashing green Valid Eva is within 2 mm from maximum detection
distance
Closed
Fast flashing red Fail safe mode Open
Flashing red No Eva programmed Open
When Adam DYN-Status operates in StatusBus mode, the following LED statuses are also possible:
LED on Adam StatusBus Description
Double flash, red
0.11/0.2/0.11/0.67 s,
Sensor in StatusBus mode, off.
“Ready slave” Address 0.
Eva is not within detection
distance during
addressing.
Double flash, green
0.11/0.2/0.11/0.67 s,
on/off/on/off
Sensor in StatusBus mode, on.
Address 0.
Addressed from 1–30 to 0.
Eva within detection
distance.
Off for 5 s, then flickering flash
0.07/1.9 s, on/off
Sensor in StatusBus mode, on.
Teach mode.
The flashing usually lasts for
1-4
seconds during the
addressing
(teach) process.
Burst with stress flash. Burst
cycle: 0.8/0.4 s, on/off
At the command from Pluto
Manager.
Visible sensor
identification.