2TLC172271M0201 Rev.H 8
Models of Adam and Eva
Eden communicates with a dynamic signal (DYNlink) generated by the control device, a Vital, a
Pluto Safety PLC or a URAX. Up to 30 Eden sensors can be connected in series to Vital 1. Ten Eden
sensors can be connected to one Pluto or URAX input, without reducing the achieved performance
level.
It is also possible to connect Tina adaptor units and E-stops in the same safety circuit. Adam and
Eva are acquired separately, and it is possible to mix different models of Adam DYN in the same
safety circuit.
Adam DYN
Adam DYN exists in different models: Adam DYN-Info, Adam C DYN-Info, Adam DYN-Reset and
Adam DYN-Status.
Adam DYN-Info M12-5
DYNlink model with information output.
Adam C DYN-Info M12-5
DYNlink model with information output and coated
electronics to provide increased resistance in demanding
environments.
Adam DYN-Reset M12-5
DYNlink model with built in monitored reset and indication
lamp output.
Adam DYN-Status M12-5
DYNlink model with StatusBus function. Adam DYN-Status is
delivered configured for static information output, but
switches to StatusBus configuration when a StatusBus
master has been detected. Requires a Pluto as master.
(For more information about the Pluto, refer to the user
manual at
new.abb.com/low-voltage/products/safety-
products)