60
10.3 Serial link signal connection
The AW400 optional serial communication P.C. Board is equipped with modular telephone RJ45 type jack
supporting both for RS 232 and RS 422/485 standards:
RJ45 TELEPHONE SIGNAL CONNECTION JACK LAY-OUT:
Pin N.
RS 232 RS 422 RS 485
1
GND
Ground
Tx +
Data transmission to PC, +
-
2
Rx IN
Data transmission from PC
Tx –
Data transmission to PC, -
-
3
Tx OUT
Data transmission to PC
GND
Ground
-
4
-
Rx +
Data transmission from PC, +
Data transmission to and from PC, -
5
-
Rx –
Data transmission from PC, -
-
6
GND
Ground
GND
Ground
Data transmission to and from PC, +
Table 13 - RJ45 Jack serial Communication connector pin-out
RJ45 Jack
Fig. 16 - RJ45 Connector layout
For RS232 and RS485 use shielded cables, two-cores twisted pair wire, section 0.5 ÷ 1.0 mm
2
.
For RS422 use shielded cable, 4 cores, twisted pairs wire, section 0.5 ÷ 1.0 mm
2
.
Connect shields to the ground shield terminal strip inside AW400.