1-2 Technical features
Power supply voltage 230 V AC +/- 10%
110 V AC +/- 10% (D1 Plus 110)
24 V AC / DC +/- 10% (D1 Plus 24)
Frequency 50-60 Hz
Protection rating IP20
Outlet type Potential-free relay exchange contact;
N.O. contact = 16(10)A / 250V~ (limited
current with Resistance for Zero Crossing
of high value);
N.C. contact = 16(2)A / 250V~
N.O./N.C. contacts = 16(2)A / 250V~ (D1
Plus 24, D1 Plus 110)
Maximum AC output N.O. 16(10)A / N.C. 16(2)A
N.O./N.C. 16(2) (D1 Plus 24, D1 Plus 110)
Operating temperature from -5°C to +55°C
Storage temperature from -10°C to +65°C
Absorption/Self-consumption 6.5 VA single channel / 7.8 VA twin channel
Cross-section of cables at terminals 1...6 mm²
CE standards LVD/EMC EN60730-2-7
Languages available on equipment Italian, English, German, French, Spanish,
Swedish, Portuguese, Dutch, Russian,
Polish, Greek
Backup in case of power failure 6 years from first switch on, guaranteed by
lithium battery
Nominal pulse voltage 4kV
Operational precision + 0.5 sec/day at 25°C