Chapter 1 - Introduction
DCS 500 / DCS 600 Service Manual VI A 1 - 3
System
OEM Des.Rev.
D C S 501B 1203- 51- 2102050- 000000000
DC Drives
Type
S = Standard
F = Fieldexciter
Product family
50 = DCS500 converter module
60 = DCS600 converter module
Bridge type
1 = single (2Q)
2 = double (4Q)
Version (Salestyp)
B = modules with SDCS-CON-2
- = for all DCS600/DCF600
Module type
Converter type current, e.g. 1203A
Rated AC voltage
4 = 220...400V
5 = 415...500V
6 = 525...600V
7 = 660...690V
8 = 700...830V
9 = 800...999V
1 = 1190V
Frequency
1 = 50/60 Hz
Power connection
- = no option (size C1...A6)
R = on the right (A7)
L = on the left (A7)
Option
Softwaretyp
15 = Multidrive
18 = Crane drive
21 = OEM
Control panel
0 = no panel
P = panel included
Fieldexciter
0 = no field exciter
1 = SDCS-FEX1
2 = SDCS-FEX2..
Fan voltage
0 = standard
5 = 400-500V only size A6
6 = 525-690V only size A6
Communication boards
0 = no comm unic ation board
5 = SDCS-COM-5-board
A = SDCS-AMC-DCx-board
C = SDCS-AMC-DC-Clasx-board
Coated version
0 = no coating
X = coated version
Special Options
UL-approval
0 = standard module with UL-certificaion
U = modification for UL-certification (C3, A6/7)
Interfaces
0 = no fieldbus module included
Current measurement modification
0 = no modification
C = CMA-2 included
M = Paralleling Master converter
S = Paralleling Slave converter
Voltage measurement modification
0 = no modification
5 = PIN=51 modified for 500 V
6 = PIN=51 modified for 600 V
7 = PIN=51 modified for 690 V
8 = PIN=51 modified for 790 V
9 = PIN=51 modified for 1000 V
A = PIN-51 modified for 235V
B = PIN-51 modified for 120V
C = PIN-51 modified for 70V
D = PIN-51 modified for 40V
X = Galvanic Isolation
Special Customer Software
000= Standard
Design revision
Thyristor type (only for disc types)
1 = ABB Lenzburg
2 = Eupec
3 = IXYS
4 = Semikron
Design rev. index
only used for internal information
typecodespecification_d_docu.dsf
Figure 1-2 Type code
3ADW000093R0701_DCS500B/DCS600_Service manual_e_g