EasyManua.ls Logo

ABB DCS 500B - Remove Faulty Thyristor

ABB DCS 500B
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 - Exchange of Thyristors for Size A6
VI A 6 - 4 DCS 500 / DCS 600 Service Manual
Remove faulty thyris-
tor
1. Replace all blown fuses and reconnect all fuses taken out du-
ring search for the faulty thyristor.
2. Remove the screws of the DC - busbar plates adjacent to the
defective thyristors.
Figure 6-3 Location of the DC - busbar plates
Note: It depends on the location of the defective thyristor which DC-
busbar plates have to be disconnected.
DC-
busbar
plates