Appendix A - Spare Parts List
3ADW000195R0501 DCS800 Service Manual e e
8.09
2-Q 4-Q CODE TYPE/DATA NOTES
1 1 3ADT220090R0022 SDCS-CMA-2 For D5 - D7 (12-pulse, hardparrallel)
1 1 DCA0019192P0001 IRDH 265-4 Inside cabinet, 10 - 990 kOhm
1 1 3ADV050058P0005 IRDH 365-4 Door mounted, 10 - 990 kOhm
1 1 3ADV050058P0001 IRDH 265-3 Inside cabinet EMBR, 2 - 200 kOhm
1 1 DCA0019711P0001 AGH 204 S For IRDH >= 690 VAC, 6-pulse
1 1 3ADV050058P0002 AGH 150 W-4 For IRDH >= 690 VAC, 12-pulse
1 1 3ADT745047P0001 T 90, 500 -1200 VAC For U >= 690 VAC, 12-pulse
3 3 3ADV050092P0015 CC 1051CP 10A/1000V 3 for T90 and capacitors
2 2 3ADV050092P0017 CC 1551CP 10A/1500V 2 for A92
1 1 3ADT780007R0002 SDCS-PIN-5x-1190 meas. Special test procedure & modified
1 1 3ADT220090R0031 SDCS-PAR-1 Hardparallel master
1 1 3ADT220090R0032 SDCS-PAR-2 Hardparallel slave
High volt. fuses for U >= 750 VAC
Power Interface U>=750 VAC
Item 8.09
Hardparrallel board 2
Insulation monitor
Voltage adaption for IRDH
Voltage adaption for IRDH
High volt. fuses for U >= 750 VAC
DC-DC transducer (Knick) A92
DESCRIPTION
Current measurement aid
Insulation monitor
Insulation monitor
Parts for 12-
p
ulse, su
pp
l
y
volta
g
e >= 800 VAC, hard
p
arallel D7P and
g
alvanic isolation
Parts for 12-pulse, supply voltage >= 800 VAC, hardparallel D7P and galvanic isolation
For U >= 690 VAC, 12-pulse, replaches Knick
8680 A1/A92
1 1 3ADN260008P0001 P42000D3-0111
High volt. transformer T90
Hardparrallel board 1
10.00
2-Q 4-Q CODE TYPE/DATA NOTES
1 1 3ADT313900R1501 SDCS-CON-4 Replaces 3ADT313900R1001
1 1 3ADT314100R1001 SDCS-PIN-4 OnBoard field up to 525 VAC
3 3 3ADC770032P0025 KTK 25 25 A / 600 V
1 1 3ADC340091R0001 VVZF 70-16xxx OnBoard field up to 525 VAC
1 1 3ADT710005P0001 KTY10-6-M4/250mm 20 A - 260 A, cable 250 mm
1 1 3ADT710005P0002 KTY10-6-M4/400mm 315 A - 1000 A, cable 400 mm
2-Q 4-Q
11.00
2-Q 4-Q CODE TYPE/DATA NOTES
3 6 3ADC340063P0001 SKKT27B/xxx MCC 26 - 16 xxx
3 3 3ADT730004R0004 UR 50 A / 660 V Blade- or knife fuse
3 3 3ADV050169P0050 UR 50 A / 600 V When used as field in D6 or D7 cabinets
2-Q 4-Q
12.00
2-Q 4-Q CODE TYPE/DATA NOTES
3 6 3ADC340063P0001 SKKT27B/xxx MCC 26 -16 xxx
3 3 3ADT730004R0005 UR 63 A / 660 V Blade- or knife fuse
2 2 3ADT754014P0001 CN2B2 4715 MS-12T-B5Axxx
3 3 3ADV050169P0080 UR 80 A / 600 V When used as field in D6 or D7 cabinets
2-Q 4-Q
13.00
2-Q 4-Q CODE TYPE/DATA NOTES
3 6 3ADC340067P0001 SKKT42B/xxx MCC 44 -16 xxx
3 3 3ADT730004R0007 UR 125 A / 660 V Blade- or knife fuse
2 2 3ADT754014P0001 CN2B2 4715 MS-12T-B5Axxx
3 3 3ADV050169P0125 UR 125 A / 600 V When used as field in D6 or D7 cabinets
Module contains:
Module contains:
Module contains:
Control board
Interface board and field supply
Fuses on SDCS-PIN-4
Cooling fan 115 V, 50/60 Hz
Semiconductor fuses (as field)
DCS800-S01-0065-04/05 & DCS800-S02-0075-04/05
(
400 V - 525 V
)
Thyristor modules
DESCRIPTION
Semiconductor fuses
Thyristor modules
Semiconductor fuses
Cooling fan 115 V, 50/60 Hz
Semiconductor fuses (as field)
Semiconductor fuses
Semiconductor fuses (as field)
DCS800-S01-0045-04/05 & DCS800-S02-0050-04/05
(
400 V - 525 V
)
DESCRIPTION
Modules D1 - D4, 20 A - 1000 A, 400 V, 525 V and 600 V
Item 10.00 to 29.00
DESCRIPTION
Temperatur sensor (D1and D2)
Temperatur Sensor (D3 and D4)
DCS800-S01-0020-04/05 & DCS800-S02-0025-04/05
(
400 V - 525 V
)
Half controlled bridge block
DESCRIPTION
Thyristor modules
Common
p
arts for modules D1 - D4, 20 A - 1000 A